Publication 1734-IN052D-EN-E - February 2005Installation InstructionsPOINT I/O Source Input ModuleCat. No. 1734-IV2, -IV4 and -IV8 Series CDescriptio
10 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005Wiring the Source Input Modules24VDCSourceInputModule StatusNetwor
POINT I/O Source Input Module 11Publication 1734-IN052D-EN-E - February 2005Wiring for 1734-IV2WARNINGWhen you connect or disconnect wiring wh
12 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005Wiring for 1734-IV4Note: When connecting more than 1 wire in a ter
POINT I/O Source Input Module 13Publication 1734-IN052D-EN-E - February 2005Wiring for 1794-IV8WARNINGWhen you connect or disconnect wiring wh
14 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005Example of Wiring for 1734-IV8 Using 2-Wire Proximity SwitchesWARN
POINT I/O Source Input Module 15Publication 1734-IN052D-EN-E - February 2005Example of Wiring for 1734-IV8 Using 3-Wire Proximity SwitchesWARN
16 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005Troubleshooting with the IndicatorsIndication Probable CauseModule
POINT I/O Source Input Module 17Publication 1734-IN052D-EN-E - February 2005Indication Probable CauseNetwork StatusOff Device is not on-line-
18 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005North American Hazardous Location ApprovalThe following informatio
POINT I/O Source Input Module 19Publication 1734-IN052D-EN-E - February 2005European Hazardous Location ApprovalEuropean Zone 2 Certification
2 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005This Series C product can be used with DeviceNet and PROFIBUS adapt
20 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005Specifications - 1734-IV2, -IV4 and -IV8 Source Input ModulesInput
POINT I/O Source Input Module 21Publication 1734-IN052D-EN-E - February 2005Environmental ConditionsOperational Temperature IEC 60068-2-1 (Tes
22 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005Field Wiring Terminations 1734-IV20 - Input 0 1 - Input 1 2 - No C
POINT I/O Source Input Module 23Publication 1734-IN052D-EN-E - February 2005
Publication 1734-IN052D-EN-E - February 2005 PN 957928-23Supersedes Publication 1734-IN052C-EN-P - April 2002 Copyright © 2005 Rockwell Automation. Al
POINT I/O Source Input Module 3Publication 1734-IN052D-EN-E - February 2005WARNINGIdentifies information about practices or circumstances that
4 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005ATTENTION Environment and EnclosureThis equipment is intended f
POINT I/O Source Input Module 5Publication 1734-IN052D-EN-E - February 2005WARNINGEXPLOSION HAZARD• Do not disconnect equipment unless power h
6 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005 Installing the Mounting BaseTo install the mounting base on the DI
POINT I/O Source Input Module 7Publication 1734-IN052D-EN-E - February 20052. Make certain the DIN rail locking screw is in the horizontal pos
8 POINT I/O Source Input Module Publication 1734-IN052D-EN-E - February 2005Removing a Mounting BaseTo remove a mounting base, you must remove
POINT I/O Source Input Module 9Publication 1734-IN052D-EN-E - February 2005Communicating with Your ModuleI/O messages are sent to (consumed) a
Commentaires sur ces manuels