Chapter 2
Introduction and Product Description
2–4
DIP Switch Orientation DIP Switch orientation (Figure 2–2) on the MCA board is as Follows:
CLOSED = “ON” = “1”
OPEN= “OFF” = “0”
Figure
2-2. DIP Switch Orientation
On On Off Off
Board Location The standard mounting position for the MCA board is Port B of the Drive
(Refer to Figure 2–3). If required, the Adapter can be mounted in Port A.
Note that each port uses different parameters to store Adapter setup and
configuration information.
Figure
2-3. MCA Board Mounted in Port B
AB0747A
J2
J3
*
*
J1J1
*
*
MultiCommunications
Adapter (MCA) Board